200 ScreenPRO-II Controller • Users Guide
5. System Setup
Sync Setup
póåÅ=pÉíìé
ScreenPRO-II Controller system setup: Step 12
S Prerequisites — Ensure that you are familiar with the Settings Menu. In
Chapter 4, refer to the “
Settings Menu” section on page 104.
In this procedure, you will set up sync parameters for the monitors and projectors
connected to the system — for the destination selected on the
Output Menu.
Use the following steps to set up sync parameters:
1. From the Home Menu, press OUTPUT to display the Output Menu.
2. On the Destination Bus, select the destination that you want to configure.
3. Press {SETTINGS} to display the Settings Menu.
4. On the Output Monitor line, select the device(s) that are affected by the sync
settings —
All, Preview, SPII Program or BPII Program.
5. On the Sync Out line, set the desired sync value — +H+V, -H-V, +H-V, -H+V or
CSync.
6. On the SOG line, select a specific “sync on green” signalOff, Standard or Tri-
Level
(for certain HD devices).
7. On the Gamma line, set the output gamma for the selected destination.
8. On the Raster Box Size line, set the size of the raster box that appears around
PIPs and Keys.
9. Press {BACK} to return to the Output Menu.
10. Repeat from step 2 to set sync parameters for additional destinations.
11. Press {HOME} to return to the Home Menu.
12. Press {SAVE} to save the new system configuration in memory.
12
Note
It is recommended that you leave the sync parameters at their
default (factory reset) values. However, should you need to
adjust individual settings for a particular monitor and projector
configuration, use the following procedure.
Important
It is recommended that you leave Gamma at the unity setting
(
1.0). Change the value only if you need to compensate for a
gamma problem in your projector or monitor.
Note
As required, you can change the Raster Box value during
operations without affecting sync settings.