ScreenPRO-II Controller • User’s Guide 129
4. Menu Orientation
System Menu
`çãã=pÉíìé=jÉåìë
Information is provided for three different Comm Setup Menus:
• Ethernet Setup Menu
• RS-232 Setup Menu
• Lantronix Setup Menu
bíÜÉêåÉí=pÉíìé=jÉåì
On the Router Specification Menu, when the Communication Type is set to
ETHERNET, press {COMM SETUP} to display the Ethernet Setup Menu:
Figure 4-31. Ethernet Setup Menu (sample)
The Ethernet Setup Menu enables you to set the selected router’s IP address and port
number.
• IP Address — sets the router’s IP address.
• IP Port Number — sets the router’s IP port number, if applicable.
• Press {NEXT IP QUAD} to advance to the next 3-digit set of numbers in the
address. Use the
ADJ knob in the normal manner to change the digits.
• Press {TEST COMM} to test communications with the defined router:
~ If the test is successful, a “ROUTER CONNECTED” message will
appear that includes the Router name and version.
~ If the test is unsuccessful, a “ROUTER FAILED” message will appear. In
this condition, re-check all connections and settings, and repeat the test.