ScreenPRO-II Controller • Users Guide 275
`K==réÖê~ÇáåÖ=pçÑíï~êÉ
Ethernet Upgrade Method
8. Click the Connect button. If the connection is successfully, the message
Connect via Ethernet successful” appears in the Flash Loader’s Status Bar. If
you cannot connect, refer to the “
Troubleshooting Ethernet Communication
section on page 275.
9. To upload files to the ScreenPRO-II Controller, click "Open script file to read and
upload
."
10. In the dialog, select "Complete_Load.sld" and click Open. The ScreenPRO-II
Controller menu should immediately display the "
System in LOADER MODE"
message.
11. It takes several minutes to load the flash memory. When complete, the Flash
Loader utility displays the “
Upload Complete” message. Click OK to continue.
12. Cycle power on the ScreenPRO-II Controller, and exit the Flash Loader utility.
13. On ScreenPRO-II Controller, perform a factory reset. In Chapter 5, refer to the
Return to Factory Default” section on page 189 for instructions.
14. On the ScreenPRO-II Controller, verify that the new software has been loaded
correctly. Press {
HOME} > SYSTEM > {SW VER} to display the Software
Version Menu
.
qêçìÄäÉëÜççíáåÖ=bíÜÉêåÉí=`çããìåáÅ~íáçå
Use the following steps to determine the IP address of ScreenPRO-II Controller, and
establish proper communications:
1. Turn on the ScreenPRO-II Controller. Press {HOME} > SYSTEM > {NETWORK
SETUP
} to display the Network Setup Menu.
2. Make a note of the IP address.
3. Attempt to ping the ScreenPRO-II Controller as follows:
a. Connect ScreenPRO-II Controller’s Ethernet port to a Hub or Switch.
b. Connect the Ethernet Hub or Switch to your PC. A totally “local” network
is recommended, without IP connections to the outside world.
c. Turn on the PC or laptop.
d. Open a command prompt window on the PC. Click Start > Programs >
Accessories > Command Prompt
.
e. On the command prompt line, type:
ping 192.168.0.2
... followed by Enter.
f. If the computer is able to successfully communicate with the
ScreenPRO-II Controller, you will see a series of “
replies” from the
target IP address. Repeat the upgrade procedure as outlined in the
Ethernet Upgrade Method” section on page 274.
Note
The default IP address is 192.168.0.2.
Note
Use the unit’s actual IP address, as determined in step 2
above.