BARCO Serial Communication User Manual 87
blanking left, write
Description :
Write a new value for blanking left.
Command :
Command[0] \x20
Command[1] \x4e
Data :
Data[0..1] = value of blanking left.
Data[0] msb of value
Data[1] lsb of value
Example :
Set the blanking left to 0 on a projector with address \x01.
Transmit
Start \xfe
Projector address \x01
Command[0] \x20
Command[1] \x4e
Data[0] \x00
Data[1] \x00
Checksum \x6f
Stop \xff
Page view 86