BARCO Serial Communication User Manual 230
lamp, read history
Description :
Read the lamp run time history list.
Command :
Command[0] \x74
Data :
No data bytes.
Projector type :
Only for projectors that don't have a memory chip attached
to the lamp. See your Owner's Manual if the "Lamp
History" item exists in the menu structure.
Return data :
Lamp[0] serial number c-language string
Lamp[0] run time see formula below
Lamp[1] serial number c-language string
Lamp[1] run time see formula below
...
Lamp[n-1] run time see formula below
Lamp[n-1] serial number c-language string
n = number of lamps stored in the history list
- c-language string (see syntax).
- formula lamp run time :
Lamp run time (hours) = Data[1]*256 + Data[0]