BARCO Serial Communication User Manual 339
projector, read run time
Description :
Read the projector run time in seconds.
Command :
Command[0] \x62
Data :
No data bytes.
Return data :
The return data-transfer being the projector run time in
seconds contains of four data bytes. The first byte is the
most significant byte !
Formula :
Projector run time (seconds)
= Data[0]*256
3
+ Data[1]*256
2
+ Data[2]*256 + Data[3]
Example :
Read the projector run time of a projector with address
\x01. Suppose the projector run time is 3000 hours
(10800000 seconds).
Transmit
Start \xfe
Projector address \x01
Command[0] \x62
Checksum \x63