BARCO Serial Communication User Manual 164
field polarity, write
Description :
Change the field polarity value.
Command :
Command[0] \x20
Command[1] \x62
Data :
Data[0] = field polarity.
Data[0]
Negative \x00
Positive \x01
Automatic \x02
Example :
Set the field polarity to automatic on a projector with
address \x01.
Transmit
Start \xfe
Projector address \x01
Command[0] \x20
Command[1] \x62
Data[0] \x02
Checksum \x85
Stop \xff