BARCO Serial Communications User Manual 37
infrared control
Example :
Select source 3 of a projector with address \x01.
Transmit
Start \xfe
Projector address \x01
Command[0] \x30
Data[0] \x12
Checksum \x43
Stop \xff
Receive (acknowledge)
Start \xfe
Projector address \x01
Command[0] \x00
Command[1] \x06
Checksum \x07
Stop \xff