ScreenPRO-II • User’s Guide 179
aK==oÉãçíÉ=`çåíêçä
Using Remote Control
oçìíÉê=pÉíìé
With your destinations properly set up, you can now set up each connected router.
Use the following procedure to set up the routers that are connected to the
ScreenPRO-II units:
1. On the Encore or ScreenPRO-II Controller console, press SYSTEM > {ROUTER
SETUP
} to display the Router Specification Menu.
Figure D-8. Router Specification Menu (sample)
2. Scroll to the Number line and select the router number that you wish to define.
If you select and assign an “
EMPTY” router number, press {ADD NEW}.
3. To continue:
~ For Barco/Folsom routers, continue with step 4.
~ For routers from other manufacturers, continue with step 5.
4. For Barco/Folsom routers, use the following steps:
Note
This procedure is not required if you are using “Internal”
source routing on your ScreenPRO-II units.
Number of Inputs
Number of Outputs
Manufacturer
FOLSOM
16
B
A
C
K
N
A
V
A
D
J
ROUTER SPECIFICATION
Number 1
16
Communication Type ETHERNET
Router Type ANALOG
COMM
SETUP
OUTPUT
PATCH
ADD
NEW
DELETE
ROUTER
[ MATRIXPRO1 ]Name
Note
After a factory reset, two default routers are pre-assigned:
MATRIXPRO1 (MatrixPRO1 16x16 Analog) and
MATRIXPRO2 (MatrixPRO2 16x16 SDI).
Note
You may test the communication for any type of router. For
Barco/Folsom routers, the input/output fields are
automatically determined. For other manufacturers, these
fields must be set manually.