max Light..................This is the panel light output that corresponds
to the maximum ambient light, measured by the
ALC sensor.
min Thresh ...............This is the minimum value of ambient light.
Below this value, ALC will remain inactive.
When the measured ambient light reaches this
value, the panel light output will be set to the
min Light value.
max Thresh ..............This is the maximum value of ambient light.
Above this value, ALC will stop controlling the
light output. When the measured ambient light
reaches this value, the panel light output will be
set to the max Light value.
Scan mode
The memory of the display contains maximum 200 fixed and 28
programmable scan modes.
When you connect a video signal, the display checks in the memory
for a matching scan mode.
If it finds one, it selects the corresponding settings and parameters
from the memory. If it does not find a matching scan mode, the
display uses default settings to display the image.
When you make adjustments and save the changes, the current scan
mode is saved as programmable scan mode. If this happens while all
programmable scan modes are occupied, the oldest programmable
scan mode is overwritten automatically.
The Scan Mode menu contains the following function:
Find next mode.........Select if you wish to select another scan mode
from memory that matches the incoming video
and sync signals. The number displayed in the
OSD is the number of the actual scan mode’s
memory location.
Factory reset
Can be used to re-initialize the display.
Actual mode .............Restores all factory parameters for the current
programmable mode.
All modes..................Restores all factory parameters for all
programmable modes.
Control wheel
This function allows you to disable the control wheel function so that
the on-screen display cannot be used.