Advanced functions
84
Measurements
The Measurements info menu contains the following items:
Scan Measurements
The Scan Measurements info menu contains the following items:
Internal Temperature The temperature measured inside the dis-
play
Sensor Temperature The internal temperature measured on the
I-Guard board
FAN speed A value indicating the speed of the fans.
Minimum speed is 0, maximum speed is
1000
Sensor Y value The luminance measured by the I-Guard,
expressed in nit (Cd/m²)
Sensor DAC value The luminance measured by the I-Guard,
expressed in DAC values
DVI Input: The current DVI input format
Resolution: The resolution of the current input signal
Clock Frequency: The current clock frequency
Hor.Total: The total number of dots, horizontally, of
the input signal
Hor.Active: The number of active dots, horizontally, of
the input signal
Hor.Blanking: The horizontal blanking of the input signal
Hor.Front Porch: The horizontal front porch of the input sig-
nal
Hor.Sync: The horizontal sync length of the input sig-
nal
Hor.Back Porch: The horizontal back porch of the input signal
Hor.Frequency: The horizontal frequency of the input signal