13. Projector control
13.3.1 Baud rate setup
What can be done?
The baudrate for a serial connection with a computer can be set up.
How to set up?
1. Press MENU to activate the menus.
2. Use the or key to select Projector control and press ENTER.
3. Use the or key to select Serial communication and press ENTER.
The serial communication menu opens.
4. Use the or key to select Baudrate and press ENTER to toggle between the available baud rates.
The following baud rates can be selected:
- 9600
- 19200
- 38400
- 57600
- 115200
5. Press EXIT to return.
Image 13-9
Image 13-10
Image 13-11
13.3.2 Interface standard
What can be done?
The communication protocol for the communication between the projector and a computer can be set to RS232 or RS422.
How to set up
1. Press MENU to activate the menus.
2. Use the or key to select Projector control and press ENTER.
3. Use the or key to select Serial communication and press ENTER.
The serial communication menu opens.
4. Use the or key to select Interface standard and press ENTER to toggle between [RS232] or [RS422].
Default: [RS232]