Hardware & SoftwareInstallation & User ManualMGP 15 Dicom Theater
Introduction10(This page intentionally left blank.)
Driver re-installation, updates or removal100Figure 406. Click “Next”.7. If you installed your driver with DualView enabled, skip to step 8.If you ins
Driver re-installation, updates or removal10110. When your system restarts, log in again using an account with administrator priveleges. DualView shou
www.barco.comB4100441 - 03August 2004
Introduction11About the systemBarco’s diagnostic display solutions are known for their image quality, fidelity and consistency.Building upon its wide
Introduction12display other images, like presentations. Calibration and stabilization is done by using the external optical sensor, which is installed
Introduction13Minimum system requirements• Windows 2000 (SP4) or Windows XP (SP1)• Pentium IV microprocessor• At least 1 free USB and COM port per pro
Introduction14DICOM Theater installation overviewTo install the DICOM Theater system completely, you have to follow these steps:1. Install the BarcoMe
Introduction15Installation examplesThis section illustrates the most common set-ups supported by Dicom Theater.a) Single-head with 1 display and 1 pro
Introduction164. Connect the I-Guard optical sensor to a free PC USB downstream connector. If the cable is not long enough, you have to use a USB boos
Introduction174. Connect a free PC COM port to the second projector RS-232 connector by means of a D-Sub9-to-D-Sub9 cable (15 m / 50 ft).5. Connect th
Introduction183. Connect a free PC COM port to the projector RS-232 connector by means of the D-Sub9-to-D-Sub9 cable (15 m / 50 ft).4. Connect the I-G
Introduction19d) Dual-head with two displays and two projectorsFigure 4BAR CORS-232USBVIDEO2RS-232BAR COVIDEO1RS-232VIDEO3VIDEO4RS-232USBVideo1 USBVi
2 MGP 15 Dicom TheaterCopyrightThis document is copyrighted. All rights are reserved. Nor this document, nor any part of it, may be reproduced or copi
Introduction20Proceed as follows:1. Connect one video output of the first display controller to the BNC input of the first projector by means of the D
Introduction21display controller, a display input and a projector input must be connected.e) Dual-head with two displays and one projector (picture-in
Introduction222. Connect the other video output of the first display controller to the BNC input of the projector by means of the DVI-to-5 BNC cable (
23Display Controller Installation
Display Controller Installation24(This page intentionally left blank.)
BarcoMed 2MP2CP Overview25BarcoMed 2MP2CP OverviewThe BarcoMed 2MP2CP Display Controller delivers a quality image with 24-bit True Color for medical v
BarcoMed 2MP2CP Overview26• Display properties control panel interface to dynamically change display settings• Control panel supports the English (U.S
BarcoMed 2MP2CP Overview27• 1920x1200, 24-bit true color
Display controller installation28Display controller installationCaution: Wear a grounded, protective ESD strap during installation or handling of the
Display controller installation29figure 7 below). By default, VGA should be enabled, switch 1 on and switch 2 off. If you decide to use a separate VGA
MGP 15 Dicom Theater 3interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference
Display controller installation30Figure 8: PCI and RAID Controller SlotsInstalling the BarcoMed 2MP2CP display controllerInstall the BarcoMed 2MP2CP c
Display controller installation316. Connect the primary display to the connector marked “VID 1” on the BarcoMed 2MP2CP display controller using the pr
Display controller installation32(This page intentionally left blank.)
33Display Controller Software Installation
Display Controller Software Installation34(This page intentionally left blank.)
Windows 2000 BarcoMed 2MP2CP software installation35Windows 2000 BarcoMed 2MP2CP software installationNote: These instructions apply to both Windows®2
Windows 2000 BarcoMed 2MP2CP software installation36Windows stops launching the “Found New Hardware Wizard”. Please be patient as this may take severa
Windows 2000 BarcoMed 2MP2CP software installation37If it determines that the Microsoft Installer is either out of date or missing, it will display th
Windows 2000 BarcoMed 2MP2CP software installation38Figure 12Driver installation6. Click “Next” on the Display Driver Wizard’s Welcome Screen to conti
Windows 2000 BarcoMed 2MP2CP software installation39 Figure 13: Sample device selection screen, the device shown in your system may be different.Cauti
4 MGP 15 Dicom Theater(This page intentionally left blank.)
Windows 2000 BarcoMed 2MP2CP software installation40click “Back” to return to the Device Selection Screen. Click “Next” to begin installing the driver
Windows 2000 BarcoMed 2MP2CP software installation41Figure 16: Windows XP Windows Logo Testing Warning9. When the screen shown in figure 17 below appe
Windows 2000 BarcoMed 2MP2CP software installation42the BarcoMed Product Install Wizard or click “Back” to return to the Welcome Screen of the BarcoMe
Windows 2000 BarcoMed 2MP2CP software installation43displays the screens shown in figure 18 below and figure 19 on page 43, click “Yes” or “Continue A
Windows 2000 BarcoMed 2MP2CP software installation44displays active. To make your MGP 15 or your displays active you must extend your desktop to these
45Display Controller Tools
Display Controller Tools46(This page intentionally left blank.)
Barco Display Tab47Barco Display TabIntroductionThe Barco Display Tab is used for gathering information about the BarcoMed Flat Panel Display(s).To ac
Barco Display Tab48Display PropertiesYou may access the Properties page of the currently selected display, which is represented by the monitor icon ab
Barco Display Tab49Figure 20
Table of Contents5Table of ContentsIntroduction ... 9About the system...
Barco Display Tab CORONIS 3MP(This page intentionally left blank.)50
BarcoMed Driver Tab51BarcoMed Driver TabIntroductionAfter the BarcoMed Windows display controller driver is installed, a new Display Properties tab is
BarcoMed Driver Tab52Figure 21: BarcoMed Driver Tab under Windows 2000 and Windows XPStatusThe Status section displays information about the current B
BarcoMed Driver Tab53ResolutionThis displays the currently selected display resolution. Monitor ConfigurationIf the options in this section are grayed
BarcoMed Driver Tab CORONIS 3MP(This page intentionally left blank.)54
BarcoMed Hardware Tab55BarcoMed Hardware TabIntroductionThe BarcoMed Hardware Tab is used for gathering information about BarcoMed display controller(
BarcoMed Hardware Tab56Using The BarcoMed Hardware TabTo access the BarcoMed Hardware Tab do the following:1. Open the “Display Properties Control Pan
BarcoMed Hardware Tab57Figure 22 BarcoMed Hardware Tab under Windows 2000 or Windows XPDeviceDisplays the current BarcoMed display controller, driver,
BarcoMed Hardware Tab58Subsystem ID: Displays the device’s PCI Subsystem ID number.SubsystemVendorID: Displays the device’s PCI Subsystem Vendor ID nu
BarcoMed Hardware Tab59detailed customer contact information. After completion of the customer contact information screen, the Wizard will then ask th
Table of Contents6Using the BarcoMed product installation wizard ... 35Driver installation...
BarcoMed Hardware Tab60This screen gathers the diagnostic data from the user’s system as described above in this document. Click the “Start Diagnostic
BarcoMed Hardware Tab613. Then click on “Support” in the drop down menu.4. Find the appropriate ImageCare Center for your country and click on the ema
BarcoMed Hardware Tab62
63Display Tools
Display Tools64(This page intentionally left blank.)
Barco DPMS Screen Saver65Barco DPMS Screen SaverIntroductionThe Barco DPMS (Display Power Management Signaling) Screen Saver allows the user to set po
Barco DPMS Screen Saver66Save AsSaves your current Barco DPMS Screen Saver settings. The name you specify will appear in the Scheme list so you can ea
Barco DPMS Screen Saver67DPMS Settings After Work DayIf you have an display controller that supports DPMS calls, then you will be able to set the DPMS
Barco DPMS Screen Saver68On Barco CORONIS displays, the I-GUARD will stabilize the image within a few seconds after the display returns to the active
Barco DPMS Screen Saver69including those who do not have administrator privileges, can create, modify or delete private schemes. When the delete butto
Table of Contents7Current Scheme... 65Save As ...
Barco DPMS Screen Saver70Figure 24: Windows XP Screen Saver Tab2. Click on the “Settings” button. The “Barco DPMS Screen Saver Control Panel” will ope
Barco DPMS Screen Saver713. Use the default schemes by selecting one of the three default schemes. Click “OK”. Then Click “OK” again. Note: If you mak
Barco DPMS Screen Saver724. Select one of the default schemes from the “Current Scheme” drop down menu.5. Set the Work Schedule by setting the beginni
Barco DPMS Screen Saver73and run the BarcoMed Product Install Wizard (please see the section Software Installation for complete instructions).Special
Barco DPMS Screen Saver74(This page intentionally left blank.)
75MediCal Pro and Dicom Theater software
MediCal Pro and Dicom Theater software76(This page intentionally left blank.)
MediCal Pro installation77MediCal Pro installationInstall MediCal Pro on the PC. Follow the instructions from the MediCal Pro User Guide.Important: Do
Using MediCal Pro78Using MediCal ProAfter installation of the hardware and software, you must start MediCal Pro. With MediCal Pro, you can calibrate t
Using MediCal Pro798. For all the devices in the configuration, define (if necessary) and select a Preset.9. After selecting the Preset, MediCal Pro s
Table of Contents8Introduction ... 85Source selection ...
Optical sensor connection80Optical sensor connectionThe optical sensor can be attached to the screen by means of Velcro, attached to the rear of the s
Optical sensor connection81Sensor position and screen resolutiona) Selected resolution of 1280 x 1024 (1024 x 1280)Figure 29b) Selected resolution of
Using Dicom Theater software82Using Dicom Theater softwareThe Dicom Theater software tool has two purposes: The first goal is to stabilize the project
Using Dicom Theater software83Stopping and starting stabilizationIntroductionStabilization starts automatically after the projector was calibrated fro
Using Dicom Theater software84Restarting stabilization manuallyTo restart the projector stabilization, proceed as follows:1. Position the cursor over
Controlling the projector85Controlling the projectorIntroductionThe projector control provides quick access to some frequently used projector function
Controlling the projector864. Select the desired input source in the Source selection section.Picture-in-picture selectionTo switch picture-in-picture
Controlling the projector87Projector control configurationUnder the Configuration tab, the user can customize the names of the sources and projectors
Controlling the projector884. Change the names of the items appearing in the Projector Control view according to your own preferences. The changed nam
Consulting projector properties89Consulting projector propertiesWith the properties, the user can query the projector for common information. All the
9Introduction
Consulting projector properties90Portrait/Landscape: The projector’s current orientationFront/Rear-Ceiling/Table:The projector’s current configuration
Troubleshooting the stabilization process91Troubleshooting the stabilization processThe projector stabilization has stopped unexpectedlyPossible cause
Troubleshooting the stabilization process92(This page intentionally left blank.)
93Troubleshooting
Troubleshooting94(This page intentionally left blank.)
95Windows 2000 display resolutionTip: These instructions apply to both Windows®2000 and Windows®XP.Setting the resolution of your Dicom Theater displa
967. Click “Yes” when asked, “Your desktop has been reconfigured. Do you want to keep these settings?” To set the resolution of the second display att
Driver re-installation, updates or removal97Driver re-installation, updates or removalReinstalling or updating your BarcoMed 2MP2CP driverNote: These
Driver re-installation, updates or removal983. To update the driver, clear the checkbox next to (figure 38) and click “Install”.Figure 384. For Window
Driver re-installation, updates or removal99Uninstalling the BarcoMed 2MP2CP driver1. Insert your BarcoMed 2MP2CP Software CD into your computer’s CD